EJA118Y Diaphragm Sealed Differential Pressure Transmitter
Brand: Yokogawa Electric CorporationDiaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly of the differential pressure transmitter, they are connected to the transmitter using capillaries filled with fill fluid.
Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters can be used to measure liquid, gas, or steam flow, as well as liquid level, density, and pressure.
They output a 4 to 20 mA DC signal corresponding to the measured pressure differential.
The transmitters also feature remote setup and monitoring through communications with the model BT200/100 BRAIN TERMINAL, CENTUM CS/XL system etc.
Features- 0.2% Accuracy
- 700 ms Response Time
- External Zero Adjustment
Specifications
Accuracy
- ± 0.2 %
Alarm
- Down-Scale: -2.5 %, 3.6 mA DC or Less
- Down-Scale: -5 %, 3.2 mA DC or Less
- Up-Scale: 110 %, 21.6 mA DC or more
Ambient Temperature Range
- -30° to 60° C (-22° to 140° F) - with Integral Indicator
- -40° to 60° C (-40° to 140° F) - General Use Typical
Approvals & Certifications
- CSA - Explosion-proof & Intrinsically Safe Approval
- EMC EN 61326-1 Class A, Table 2, EN 61326-2-3
- FM - Explosion-proof & Intrinsically Safe Approval
- IECEx - Intrinsically Safe, Typical N & Flameproof Approval
- NAMUR NE43 Compliant
- PED 97/23/EC
- TIIS - Flameproof & Intrinsically Safe Approval
Approvals & Certifications
- Leak Test
- Mill Certificate
- Pressure Test
Cable Material
- Polyethylene Insulated PVC Sheathed
Capillary Length
- 3.3 to 32.8 feet (1 to 10 metres)
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART
- PROFIBUS PA
Damping Adjustment
- 0.2 to 64 seconds - Set in 9 Increments
Diaphragm Material
- JIS 316L Stainless Steel
Display
- LCD Display
Electrical Connectors
- 1/2" NPT Female
- G 1/2" Female
- M20
- PG13.5
Electrical Protection
- Lightning Protection
Enclosure Finish
- Deep Sea Moss Green (Munsell 0.6 GY3.1/2.0)
- Epoxy Resin-Baked Coating
- Polyurethan Resin Baked Finish
Enclosure, Body Material
- Cast Aluminum Alloy - Amplifier Housing
- JIS SCS14A Stainless Steel - Amplifier Housing
Environmental Protection
- IP67
- NEMA 4X
Fill Material
- Ethylene Glycol
- Fluorinated Oil
- Silicone Oil
Flange Material
- JIS S25C
- JIS SCA14A - Cover Flange
- JIS SCM435 - Cover Flange Bolts Material
- JIS SUS304
- JIS SUS316
- JIS SUS630 - Cover Flange Bolts Material
Flange Size - 3” (DN 80)
- 3" (DN 80) - 150# ANSI / JPI
- 3" (DN 80) - 300# ANSI / JPI
- 3" (DN 80) - JIS 10K
- 3" (DN 80) - JIS 20K
- 3" (DN 80) - PN 10
- 3" (DN 80) - PN 16
- 3" (DN 80) - PN 25
- 3" (DN 80) - PN 40
Flange Size - 4” (DN 100)
- 4" (DN 100) - 150# ANSI / JPI
- 4" (DN 100) - 300# ANSI / JPI
- 4" (DN 100) - JIS 10K
- 4" (DN 100) - JIS 20K
- 4" (DN 100) - PN 10
- 4" (DN 100) - PN 16
- 4" (DN 100) - PN 25
- 4" (DN 100) - PN 40
Fluid Specific Gravity
- 0.94 to 1.09 - Silicone Oil
- 1.09 - Ethylene Glycol
- 1.90 to 1.92 - Fluorinated Oil
Humidity
- 5 to 100 % RH (At 40° C) - Ambient Humidity
Input Impedance
- 10 kΩ or more at 2.4 kHz
Load
- 0.22 µF or Less - Load Capacitance
- 250 to 600 ohms - Digital Communication
- 3.3 MH or Less - Load Inductance
Materials of Construction
- JIS 304 Stainless Steel - Tag Plate
- JIS 316 Stainless Steel - Tag Plate
Mounting
- 2" (50.8 mm) Pipe - Transmitter
- Flange Mount - Diaphragm Seals
NACE & NIST
- NACE
O-Ring Material
- Fluororubber
Operating Temperature
- Maximum
Output
- 4-20 mA DC, 2-Wire System with Digital Communication
Power Supply Effect
- ± 0.005 % per Volt (From 21.6 - 32 Vdc, 350 ohms)
Pressure Range
- bar: -5 to 5
- inH₂O: -2,000 to 2,000
- kPa: -500 to 500
- mmH₂O: -10,000 to 10,000
- psi: -72.52 to 72.52
Pressure Type
- Absolute
- Differential
Process Temperature
- -50° to 300° C (-58° to 572° F)
Response Time
- 0.5 second, Max.
Screw Material
- 316 Stainless Steel - Zero-Adjustment Screw & Set Screws
Static Pressure Effect
- Total Shift: ± 0.14 % / 0.98 MPa (10 kgf/cm²)
- Zero Shift: ± 0.1 % / 0.98 MPa (10 kgf/cm²)
Supply Pressure
- psia: 0.38 (kPa: 2.7, bar: 0.027)
Supply Voltage
- 10.5-28 Vdc - for TIIS Intrinsically Safe Typical
- 10.5-30 Vdc - for Intrinsically Safe, Typical N, Non-Incendive, or Non-Sparking Typical
- 10.5-32 Vdc - for Lightning Protector
- 10.5-42 Vdc - for General Use & Flameproof Typical
- 16.4-42 Vdc - Communication Line
Temperature Effect
- ± 1.4 %/50° C (122° F) - Total Shift Ambient Temperature Effect
Update Time
- 0.125 second
Wetted Materials
- JIS 304 Stainless Steel PVC Sheathed - Protection Tube
- JIS 316 Stainless Steel - Pipe, Capillary Tube
Zero Offset
- 0.01 % of Span - Continuously Adjustable Resolution
Documentation
Data Sheets
- EJA Series Fieldbus Communication pdf 939 KB
- EJA Series Fieldbus Communication Type pdf 225 KB
- EJA Series HART Protocol pdf 363 KB
- EJA Series PROFIBUS PA Communication pdf 930 KB
- EJA Series With HART® Communication Differential Pressure Transmitter pdf 1,000 KB
- EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters pdf 2.1 MB
Manual
- EJA Series Differential Pressure and Pressure Transmitters Installation Manual *See Manual Change 15-009 16-004 16-018 pdf 4.8 MB
- EJA Series Fieldbus Communication Type *See Manual Change 10-007 12-004 16-004 pdf 1.4 MB
- EJA Series PROFIBUS PA Communication Type *See Manual Change 10-007 12-004 16-004 pdf 5.2 MB
- Manual Change 10-007 12-004 16-004 pdf 293 KB
- Manual Change 16-004 16-018 pdf 232 KB