Description
- Field scanning and communication interface for tank inventory applications with optional embedded tank inventory calculation functionality.
Application
- For all applications requiring accurate and reliable process and inventory data, such as refineries, tank farms and terminals. Data is suitable for custody transfer, safe product transfer and tank farm operation
Legal Metrology and Custody Transfer
- Compliant to API-standards as stated by approval and certification by notified bodies as NMI.
Tank Database
- 80 tanks (one gauge per tank) 40 tanks (two gauges per tank)
Redundancy
- Hot standby, real-time synchronization (redundancy controlled by Entis Pro, ENTIS or modbus host)
Supported Gauge Models
- All GPU enabled tank gauges (such as 811, 813, 866, 854, 872, 873, 877, 894, 990, 954) & Emerson TRL/2
Gauge Commands
- • Lock test • Unlock • Block • Freeze • Calibrate (854, 894) • Density dip • Alarm test (SmartRadar) • Water dip • Density profile
Tank Scanning
- 6 field ports sequential and/or parallel, refresh rate 2-4 sec.
Inventory Calculations
- Conform API MPMS Ch. 12.1
Tank Capacity Tables (strapping tables)
- Up to 5000 straps per tank, 400000 straps total
Support API/ASTM Product Calculations
- ASTM D1250-80; conform Vol. X—Tables, 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60 Commodities Product groups A, B, C & D
- API MPMS Ch. 11.1 (2007; adj. to ASTM D1250-04 and IP-200)—Tables, 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60; Product groups A, B, C, D
- API MPMS Ch. 11.2.4 (GPA TP-27)—Tables, 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60; Product group E
- ASTM D4311-83—Tables 1 and 2
- ASTM D4311-96—Table 1
- ASTM D4311-04—Tables 1 and 2
- ASTM D4311-15
- ASTM D4311M-15
- ASTM D1555-16
- ASTM D1555M-16
Support Other Product Calculations
- EN 15940-19 (Hydrogenated Vegetable Oil)
- SGS-21 (Ammonia)
- NBR15639-16 (Ethanol / Alcohol)
- User configurable density table
- User configurable CTL table
- User configurable concentration table
Modbus TCP/IP and / or OPC UA TCP
- EN 15940-19 (Hydrogenated Vegetable Oil)
- SGS-21 (Ammonia)
- NBR15639-16 (Ethanol / Alcohol)
- User configurable density table
- User configurable CTL table
- User configurable concentration table
Available Gauge Data
- • Product level • Gauge status and alarms • Product temperature • Vapor temperature • Vapor pressure • Ambient temperature • Water level • Observed density (Servo, HTG, HIMS) • Temperature Profiles • Density Profiles • Product pressure • Floating roof levels
Available (Calculated) Inventory Data
- Volume (TOV, GOV, GSV, NSV)
- Mass (Liquid, vapor, total)
- Reference density
- Volume correction factor (VCF, CTL)
- S&W, Vapor (4 types), DCF, TCF, manual CTL
- Volume derived flow
Clock & Time Synchronization
- External using Entis Pro, ENTIS or Modbus host systems such as DCS
Supported Engineering Units
- Level m, mm, ft, in, in/16 and ft-in-16 (fis)
- Temperature °C, °F
- Density kg/m3, °API, lb/ft3, RD60, lb/USgal
- Pressure kgf/cm2, kPa, psi(g), Pa
- Volume m3, USgal, bbl, l(L)
- Mass/Weight kg, lb, metric ton, long ton, US ton
- Flow m3/min, m3/h, l/min, bbl/min, bbl/h, USgal/min, USgal/h, UKgal/h
Available Tank Correction Methods
- CTSh3 • Floating Roof Weight • Temperature GRH • Pressure GRH • Servo Wire correction • Floating Roof Immersion Compensation (RIC)
Temperature and Density Profiles
- Temperature profiles - Periodic scanning of temperature profiles data up to 16 points from BPM and TRL/2 gauges and presentation in Modbus output (RTU and TCP/IP) and OPC UA TCP output based on configuration.
- Density profiles - Density profiles data collection up to 50 density points from Honeywell Servo gauges and presentation in Modbus output and OPC UA TCP output based on user command.
Serial Ports
- 2x modbus serial (+ 4 additional ports by using optional slots)
Supported Host Protocols
- Serial modbus (Slave) • CIU 858 emulation • CIU 880 Prime/Plus emulation (serial modbus)
Ethernet/LAN
- 3x Modbus TCP/IP and / or OPC UA TCP ethernet (FTEA, FTEB and Office LAN)
Field Ports
- 6x option slots (of which 4 ports can be used for serial host connectivity)
Wireless Connectivity
- ISA 100 via Honeywell WDM
Available Option Boards
- Enraf BPM fieldbus, Serial modbus (master) and Serial GPU input and TRL/2 Fieldbus
Electrical Safety
- IEC 61010-1:2010 (3rd edition)
- EN 61010-1:2010
European Directives
- CE: • 2006/95/EC (Low voltage directive) • 2004/108/EC (EMC) • CAN/CSA C22.2 No. 61010-1-12 • UL Standard: 61010-1 (3rd Edition)
Self Monitoring & Diagnostics
- Designed for compliance with NAMUR NE 107
Legal Metrology (Weight & Measures)
Physical Layer
- 2-wire Bi-phase mark modulated (MIL-STD-1553)
Typical No. Field Devices
- 10-15, depending on cable spec and length
Distance
- 10 km or more depending on cable characteristics
Type of Galvanic Isolation
- Transformer coupled with ground shield