HIMHART Smart HART Loop Interface & Monitor
Brand: Yokogawa Electric CorporationThe HIMHART Loop Interface and Monitor unlocks the full potential of new and in-place smart HART multivariable transmitters and valves.
Converts HART to 4-20 mA Signals: The HIM allows up to three additional Analog process variable measurements from a smart device with no additional process penetrations or wiring.
Take Full Advantage of “Legacy” Instruments: The HIM lets you leave trusted (and paid for) smart HART transmitters and valves in place, yet still take advantage of all the information they have to offer.
Features- "Break Out" up to three analog signals proportional to a HART primary, second, third or fourth variables of multivariable transmitters
- High/Low process and loop diagnostic alarms
- Normal or Burst HART Modes
- Sets up as a Primary or Secondary Master, or in "Listen" Mode
- Large, 5-digit display
- Isolated output channels
Specifications
Accuracy
- ± 0.015 % of, Max.
Alarm
- Process High/Low Alarms
Approvals & Certifications
- CE
- CSA
- EMC Directive 89/336/EEC, EN 61326
Communication
- Baud Rate: 300 to 19,200 bit/sec
- Data Length: 8-bits - Character Format
- HART
- RS-485 Modbus RTU Communication Protocol
- Start Bit: 1-bit - Character Format
- Stop Bit: 1-bit - Character Format
Consumption
- 2 to 3.5 W, Nominal
- 4.5 W at 24 Vdc, Max.
Delay Time
- 0 to 120 seconds Programmable - Alarm Trip Delay
Diagnostics
- Process & Status High/Low Alarm
Display
- 2-Digit HART Address Indicator
- -99999 to 99999
- Bottom Row, 0.225" (6 mm) High Digits on a Reflective Background
- Large, 5-Digit Display
- Top Row, 0.4" (10 mm) High Black Digits on a Reflective Background
- Two-Line LCD Display
Electrical Connectors
- Terminal Blocks Can Accommodate 14 to 22 AWG Solid Wiring (Torque to 4 in/lb, max.
Electrical Contacts
- Normally Closed
- Normally Open
Electrical Rating
- 5 A at 250 Vac, 50/60 Hz
Environmental Protection
- Hazardous Area Class I, Div. 2, Groups A, B, C, D
- Non-Incendive Apparatus Class I, Div. 2, Groups A, B, C, D
Humidity
- 0 to 95 % Non-Condensing - Relative Humidity
Indication
- Green Status LED of Alarm Off - TRIP 1 & 2 LED
- LED - Dual Color Red/Green Indicates Input & Ready Status
- Red Status LED of Alarm on - TRIP 1 & 2 LED
Input
- ± 5 Vdc Protection - Input Over-Range
Input Impedance
- 150 ohms - Transmit Mode
- Less than 5 kΩ - Receive Mode
Isolation
- 1,000 Vrms between Case, Input, Outputs & Power Terminals
- 1,500 Vac Dielectric Strength Test for One Minute with No Breakdown
- 500 Vrms - Channel to Channel Isolation
Line Voltage Effect
- ± 0.005 % of Output Span for a 1 % Change in Line Voltage
Load
- 1,100 ohms - for Communications
- 250 ohms - for Communications
Load Effect
- ± 0.01 % of Span from 0 To, Max.
Mounting
- Surface
- Top Hat DIN Rail Mounting
Operating Temperature
- -25° to 70° C (-13° to 158° F) - Relay Range for Ambient Conditions
- -25° to 85° C (-13° to 185° F) - Display Range for Ambient Conditions
- -40° to 85° C (-40° to 185° F) - for Ambient Conditions
Output
- 0-20 mA: Fail Low to 0 mA or Fail High to 23.6 mA - Output Limits on Input Failure
- 4-20 mA: Fail Low to 3.6 mA or Fail High to 23.6 mA - Output Limits on Input Failure
- Ripple: < 10 mV Peak-to-Peak when Measured Across A 250 ohms Resistor
Output Noise
- 100 dB at 50/60 Hz - Common Mode for Noise Rejection
Power
- 24 Vdc ± 10 %
Response Time
- < 120 mss, 10 to 90 % - Output Response Time
- 150 ms + Digital Response Time - Alarm Response Time
- 333 ms, max.
- 500 ms, max.
RFI/EMI Effect
- 20 V/m at 20 to 1,000 MHz, 1 kHz AM, when Tested According to IEC 1000-4-3-1995 - RFI/EMI Immunity
- 30 V/m at 20 to 1,000 MHz, 1 kHz, when Tested According to IEC 1000-4-3-1995 - RFI/EMI Immunity
Span - Maximum
- 125 % of Span Typical - Output Limiting
- 130 % of Span - Output Limiting
Span - Minimum
- 1.00 - Min. Display Span
Storage Temperature
- -25° to 70° C (-13° to 158° F) - Relay Range for Ambient Conditions
- -25° to 85° C (-13° to 185° F) - Display Range for Ambient Conditions
- -40° to 85° C (-40° to 185° F) - for Ambient Conditions
Switch Type
- DPDT Relay, 1 Form C
- SPDT Relay, 1 Form C
Temperature Effect
- ± 0.0065 % of Span/°C, Max.
Update Time
- 100 ms - Display Update Rate
Works with Every Smart HART Device: With a very simple PC program, the HIM programs in minutes to interface with every HART-compatible monitoring and control device:
- Multivariable Mass Flow Transmitters
- Dual-Sensor Temperature Transmitters
- Pressure Transmitters
- Coriolis, Magnetic, Ultrasonic and Vortex Flow Meters
- pH Transmitters
- Radar and Hydrostatic Level Transmitters
- Valve Positioners and Damper Operators