EJX438A Gauge Pressure Transmitter
Brand: Yokogawa Electric CorporationDiaphragm seal is used to prevent process medium form entering directly into the pressure-sensing assembly of the pressure transmitter, it is connected to the transmitter using capillary filled with fill fluid.
EJX438A Diaphragm Sealed Gauge Pressure Transmitters can be used to measure liquid, gas, or steam pressure. EJX438A outputs a 4-20 mA DC signal corresponding to the measured pressure.
It also features quick response, remote setup and monitoring via BRAIN or HART communications, and diagnostics and optional status output for pressure high/low alarm.
The multi-sensing technology provides the advanced diagnostic function to detect such abnormality as an impulse line blockage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available.
All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TUV as complying with SIL 2 for safety requirement.
Features- ± 0.15% Accuracy
- 200 ms Response Time
- Exida and TUV SIL2 / SIL3 Certified
- Capillary Fill Fluid Density Compensation
- Local Parameters Setting (LPS)
Specifications
Accuracy
- ± (0.1 + 0.005 URL/Span) % of Span (Includes Terminal-based Linearity, Hysteresis & Repeatability)
- ± 0.15 % of Span (Includes Terminal-based Linearity, Hysteresis & Repeatability)
Adjustment Type
- Push Button
- Screw - External Zero Adjustment
Alarm
- Down-Scale: -5 %, 3.2 mA DC or Less
- Up-Scale: 110 %, 21.6 mA DC or more
Ambient Temperature Range
- -30° to 60° C (-22° to 140° F) - LCD Display
- -40° to 60° C (-40° to 140° F)
Approvals & Certifications
- Leak Test
- Material Certificate
- Pressure Test
- SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000
- TÜV (Technischer Uberwachungsverein)
Approvals & Certifications
- ATEX - Flameproof & Intrinsically Safe
- CSA - Explosion-proof & Intrinsically Safe
- EMC EN 61326-1 Class A (For Industrial Locations), EN 61326-2-3 & EN 61326-2-5 (Fieldbus)
- FM - Explosion-proof & Intrinsically Safe
- IECEx - Flameproof & Intrinsically Safe
- NAMUR NE43
- PED 2014/68/EU - Sound Engineering Practice
- PED 97/23/EC - Sound Engineering Practice
Cable Material
- Polyethylene Insulated PVC Sheathed
Capillary Length
- 0 to 32.80 ft (0 to 10 metres)
Capillary Material
- JIS SUS316 - Capillary Tube
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART
- PROFIBUS PA
Current
- 6,000 A, Max.
Damping Adjustment
- 0 to 100 seconds
Dead Time
- 45 ms (Nominal)
Diagnostics
- Configuration Error
- CPU Failure
- Hardware Failure
- Process Alarm for Pressure or Capsule Temperature
Diaphragm Material
- 316L Stainless Steel
- Hastelloy C-276
- Tantalum
- Titanium
Display
- 10-Segment Signal Characterizer (User-Configurable)
- 5-Digit Numerical Display
- 6-Digit Unit Display
- Bar Graph
- LCD Display
Distance
- Up to 2 Kilometers (1.25 Miles) - Communication Distance
Drain, Vent Valves & Plug
- 316 Stainless Steel
Electrical Connectors
- 1/2" NPT Female
- 1/4" NPT - Vent/Drain Plugs
- G 1/2" Female
- M20 Female
- R: 1/4" - Vent/Drain Plugs
Electrical Protection
- Lightning Protection
Enclosure Finish
- Anti-Corrosion Coating
- Polyurethane, Mint-Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)
Enclosure, Body Material
- ASTM CF-8M Stainless Steel - Amplifier Housing
- Low Copper Cast Aluminum Alloy - Amplifier Housing
Environmental Protection
- IP66
- IP67
- NEMA 4X
Fill Material
- Ethylene Glycol
- Fluorinated Oil
- Silicone
Flange Material
- 304 Stainless Steel
- 316 Stainless Steel
- 316L Stainless Steel - Coverflange Bolts & Nuts Material
- 660 Stainless Steel - Coverflange Bolts & Nuts Material
- ASTM CF-8M - Cover Flange
- B7 Carbon Steel - Coverflange Bolts & Nuts Material
- JIS S25C - Process Flange
Flange Size - 1-1/2” (DN 40)
- 1-1/2" (DN 40) - 150# ANSI / JPI
- 1-1/2" (DN 40) - 300# ANSI / JPI
- 1-1/2" (DN 40) - 600# ANSI / JPI
- 1-1/2" (DN 40) - JIS 10K
- 1-1/2" (DN 40) - JIS 20K
- 1-1/2" (DN 40) - JIS 40K
- 1-1/2" (DN 40) - JIS 63K
- 1-1/2" (DN 40) - PN 10
- 1-1/2" (DN 40) - PN 16
- 1-1/2" (DN 40) - PN 25
- 1-1/2" (DN 40) - PN 40
- 1-1/2" (DN 40) - PN 64
Flange Size - 2” (DN 50)
- 2" (DN 50) - 150# ANSI / JPI
- 2" (DN 50) - 300# ANSI / JPI
- 2" (DN 50) - 600# ANSI / JPI
- 2" (DN 50) - JIS 10K
- 2" (DN 50) - JIS 20K
- 2" (DN 50) - JIS 40K
- 2" (DN 50) - JIS 63K
- 2" (DN 50) - PN 10
- 2" (DN 50) - PN 16
- 2" (DN 50) - PN 25
- 2" (DN 50) - PN 40
- 2" (DN 50) - PN 64
Flange Size - 3” (DN 80)
- 3" (DN 80) - 150# ANSI / JPI
- 3" (DN 80) - 300# ANSI / JPI
- 3" (DN 80) - 600# ANSI / JPI
- 3" (DN 80) - PN 10
- 3" (DN 80) - PN 16
- 3" (DN 80) - PN 25
- 3" (DN 80) - PN 40
- 3" (DN 80) - PN 64
Flange Size - 4” (DN 100)
- 4" (DN 100) - 150# ANSI / JPI
- 4" (DN 100) - 300# ANSI / JPI
- 4" (DN 100) - JIS 10K
- 4" (DN 100) - JIS 20K
- 4" (DN 100) - JIS 40K
- 4" (DN 100) - PN 10
- 4" (DN 100) - PN 16
- 4" (DN 100) - PN 25
- 4" (DN 100) - PN 40
Fluid Specific Gravity
- 0.94 to 1.09 - Silicone Oil
- 1.09 - Ethylene Glycol
- 1.90 to 1.92 - Fluorinated Oil
Gasket Material
- 316 Stainless Steel (Hoop) - Spiral Gasket for Transmitter Side
- PTFE Teflon (Filler) - Spiral Gasket for Transmitter Side
Humidity
- 0 to 100 % RH - Ambient Humidity Limit
Indication
- Digital
Input Impedance
- 10 kΩ or more at 2.4 kHz - Communicating Device
Load
- 0 to 1,290 ohms - for Operation
- 0.22 μF or Less - Load Capacitance
- 250 to 600 ohms - Digital Communication
- 3.3 MH or Less - Load Inductance
Materials of Construction
- 304 Stainless Steel - Mounting Brackets
- 316 Stainless Steel - Name Plate & Tag, Mounting Brackets
Mounting
- 2" Pipe Mounting - Transmitter
Mounting Position
- Horizontal
NACE & NIST
- NACE MR-0103
- NACE MR-0175, ISO 15156
O-Ring Material
- Buna-N - Cover O-Ring
- Fluororubber - Cover O-Ring
Output
- 3.6 - 21.6 mA
- 4-20 mA DC - 2-Wire
Output Format
- Transistor Contact Output (Sink Typical) at Rating 10.5-30 Vdc, 120 mA DC, Max.
Power Supply Effect
- ± 0.005 % per Volt (From 21.6 - 32 Vdc, 350 ohms)
Pressure Range
- bar: -1 to 160
- kPa: -100 to 16,000
- psi: 5 to 2,300
Pressure Type
- Absolute
- Gauge
Process Connection Style
- Extended Typical
- Flush Typical
Process Temperature
- -50° to 310° C (-58° to 590° F)
Response Time
- 200 ms
Supply Pressure
- psi: 0.38 to 14.5 (kPa: 2.7 to 100, bar: 0.026 to 1)
Supply Voltage
- 10.5-30 Vdc - Intrinsically Safe, Typical N or Non-Incendive
- 10.5-32 Vdc - Lightning Protector
- 10.5-42 Vdc - General Use & Flameproof Typical
- 24 Vdc, up to 550 ohms Load
- Minimum 16.6 Vdc - Digital Communications, BRAIN & HART
Temperature Effect
- ± (0.5 % of Span + 0.025 % of URL) Per 28° C (50° F) - Ambient Temperature Effect
Update Time
- 45 ms - Pressure
Wetted Materials
- 316L Stainless Steel
- Hastelloy C-276
- Tantalum
- Titanium
Zero Offset
- 0.01 % Incremental Resolution of Span - External Zero is Continuously Adjustable
Documentation
Data Sheets
- EJX Series FOUNDATION Fieldbus Communication pdf 878 KB
- EJX Series HART 5/HART 7 Communication pdf 2.5 MB
- EJX Series PROFIBUS PA Communication pdf 853 KB
- EJX438A Diaphragm Sealed Gauge Pressure Transmitter pdf 2.0 MB
- EJX438A Diaphragm Sealed Gauge Pressure Transmitter (Inner Diaphragm type) pdf 1.7 MB
Certificate
Manual
- DPharp BRAIN Communication Type pdf 2.7 MB
- DPharp Fieldbus Communication Type pdf 3.7 MB
- DPharp HART 5/7 Communication Type pdf 12.2 MB
- DPharp PROFIBUS PA Communication Type pdf 6.2 MB
- EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual pdf 7.2 MB
- EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 622 KB
- EJX118A, EJX438A, EJA118E, EJA438E Diaphragm Sealed Differential Pressure and Pressure Transmitter pdf 5.1 MB
- Manual Change 22-24E: EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters pdf 186 KB
- Manual Change 22-25E: EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 312 KB
- Manual Change No. 21-35E Rev.1 and 23-02E: EJX210A/EJA210E Flange Mounted and EJX118A/EJA118E/EJX438A/EJA438E Diaphragm Sealed pdf 534 KB