Extech EN510

Brand: FLIR Systems, Inc

The convenient Extech EN510 is a 10-in-1 environmental meter that can measure air velocity, air flow, air temperature, Type-K temperature, heat index, and humidity. 

It also offers wet bulb, dew point, windchill, and light level measurements. The EN510 includes a built-in, replaceable low friction ball bearing mini vane wheel, a precision photo diode with cosine and color correction filter, and a capacitive humidity sensor for high accuracy. 

The Type-K input accepts standard Type K Thermocouple probes to measure surface temperature up to 1300°C (2372°F). 

The large dual LCD display is backlit for easy use in dimly lit areas, and auto power off (with disable) helps save the battery.

Specifications

Warranty

  • 2 years

Air Velocity (ft/min)

  • 80 to 3937 ft/min

Air Velocity (ft/min) Basic Accuracy

  • ± 3 % full scale

Air Velocity (ft/min) Maximum Resolution

  • 1 ft/min

Air Velocity (km/h)

  • 1.4 to 72 km/h

Air Velocity (km/h) Basic Accuracy

  • ± 3 % full scale

Air Velocity (km/h) Maximum Resolution

  • 0.1 km/h

Air Velocity (knots)

  • 0.8 to 38.8 knots

Air Velocity (knots) Basic Accuracy

  • ± 3 % full scale

Air Velocity (knots) Maximum Resolution

  • 0.1knots

Air Velocity (m/s)

  • 0.4 to 20 m/s

Air Velocity (m/s) Basic Accuracy

  • ± 3 % full scale

Air Velocity (m/s) Maximum Resolution

  • 0.1 m/s

Air Velocity (mph)

  • 0.9 to 44.7MPH

Air Velocity (mph) Basic Accuracy

  • ± 3 % full scale

Air Velocity (mph) Maximum Resolution

  • 0.1 mph

Air Volume (CFM)

  • 0.847 to 1,271,300

Air Volume (CFM) Maximum Resolution

  • 0.001CFM

Air Volume (CMM)

  • 0.024 to 36,000

Air Volume (CMM) Maximum Resolution

  • 0.001 cmM

Dew Point Maximum Resolution

  • 0.1°

Heat Index

  • 32 to 212° F (0 to 100° C)

Heat Index Maximum Resolution

  • 0.1°

Light (Foot Candle)

  • 0 to 1860 Fc

Light (Foot Candle) Basic Accuracy

  • 0.1Fc

Light (Foot Candle) Maximum Resolution

  • ± 5 %

Light (Lux)

  • 0 to 20,000 Lux

Light (Lux) Basic Accuracy

  • 1 Lux

Light (Lux) Maximum Resolution

  • ± 5 %

Relative Humidity Basic Accuracy

  • ± 0.4 %

Relative Humidity Maximum Resolution

  • 0.1%

Temperature (Air)

  • 32° to 122° F (0° to 50° C)

Temperature (Air) Basic Accuracy

  • ± 2.5° F (± 1.2° C)

Temperature (Air) Maximum Resolution

  • 0.1°

Temperature (Contact)

  • -148° to 2372° F (-100° to 1300° C)

Temperature (Contact) Basic Accuracy

  • ± (0.4 % + 1.8° F), ± (0.4 % + 1° C)

Temperature (Contact) Maximum Resolution

  • 0.1°

Wet Bulb

  • 22.2 to 120° F (-5.4 to 49.0° C)

Wet Bulb Maximum Resolution

  • 0.1°

Windchill

  • 15 to 112° F (-9.4 to 44.2° C)

Windchill Basic Accuracy

  • ± 3.6° F (± 2° C)

Windchill Maximum Resolution

  • 0.1°

Vane

  • ~1" (27 mm)

Relative Humidity

  • 10 to 95 %

Dew Point

  • -13.5 to 120.0° F (-25.3 to 49.0° C)
show more