SW 4048 120/240

Price
Request a Quote
Stock
Out of Stock

Specifications

Output Power (Continuous) at 25° C

  • SW 4024 120/240: 3400 W
  • SW 4048 120/240: 3800 W

Output Power (30 min) at 25° C

  • SW 4024 120/240: 4000 W
  • SW 4048 120/240: 4400 W

Output Power (5 sec) at 25° C

  • SW 4024 120/240: 7000 W
  • SW 4048 120/240: 7000 W

Peak Current

  • SW 4024 120/240: 41 A
  • SW 4048 120/240: 41 A

Output Frequency

  • SW 4024 120/240: 50/60 Hz selectable
  • SW 4048 120/240: 50/60 Hz selectable

Output Voltage

  • SW 4024 120/240: 120/240 Vac
  • SW 4048 120/240: 120/240 Vac

Output Wave form

  • SW 4024 120/240: True sine wave
  • SW 4048 120/240: True sine wave

Optimal Efficiency

  • SW 4024 120/240: 92 %
  • SW 4048 120/240: 94 %

Idle Consumption Search Mode

  • SW 4024 120/240: < 11 W
  • SW 4048 120/240: < 11 W

Input DC Voltage Range

  • SW 4024 120/240: 20 - 34 Vdc
  • SW 4048 120/240: 40 - 68 Vdc

AC Connections

  • SW 4024 120/240: Single / Split phase
  • SW 4048 120/240: Single / Split phase

Output Current

  • SW 4024 120/240: 90 A
  • SW 4048 120/240: 45 A

Nominal Output Voltage

  • SW 4024 120/240: 24 Vdc
  • SW 4048 120/240: 48 Vdc

Output Voltage Range

  • SW 4024 120/240: 12-32 Vdc
  • SW 4048 120/240: 24 - 64 Vdc

Charge Control

  • SW 4024 120/240: 2- or 3-Stage
  • SW 4048 120/240: 2- or 3-Stage

Charge Temperature Compensation

  • SW 4024 120/240: Yes - BTS included
  • SW 4048 120/240: Yes - BTS included

AC Input Power Factor

  • SW 4024 120/240: > 0.98
  • SW 4048 120/240: > 0.98

Input Current

  • SW 4024 120/240: 13 A
  • SW 4048 120/240: 12 A

Input AC Voltage

  • SW 4024 120/240: 120 / 240 Vac split phase
  • SW 4048 120/240: 120 / 240 Vac split phase

Input AC Voltage Range Line to Neutral

  • SW 4024 120/240: 95 - 135 Vac single phase 170 - 270 Vac
  • SW 4048 120/240: 95 - 135 Vac single phase 170 - 270 Vac

Dead Battery Charge

  • SW 4024 120/240: Yes
  • SW 4048 120/240: Yes

Tare Loss

  • SW 4024 120/240: 29 W
  • SW 4048 120/240: 27 W

Compatible Battery Types

  • SW 4024 120/240: FLA, Gel, AGM, Custom
  • SW 4048 120/240: FLA, Gel, AGM, Custom

Transfer Relay Rating

  • SW 4024 120/240: 30 A
  • SW 4048 120/240: 30 A

Transfer Time (AC to inverter and inverter to AC)

  • SW 4024 120/240: < 1 cycle (16.7 ms)
  • SW 4048 120/240: < 1 cycle (16.7 ms)

Optimal Operating Temperature Range

  • SW 4024 120/240: -20° to 60° C (-4° to 140° F)
  • SW 4048 120/240: -20° to 60° C (-4° to 140° F)

Storage Ambient Temperature Range

  • SW 4024 120/240: -40° to 85° C (-40° to 185° F)
  • SW 4048 120/240: -40° to 85° C (-40° to 185° F)

Humidity Operation / Storage

  • SW 4024 120/240: < 95 % RH, Non-Condensing
  • SW 4048 120/240: < 95 % RH, Non-Condensing

Ingress Protection Rating

  • SW 4024 120/240: Indoor only, IP20
  • SW 4048 120/240: Indoor only, IP20

Altitute (Operating)

  • SW 4024 120/240: 2000 m (6562 ft)
  • SW 4048 120/240: 2000 m (6562 ft)

Product Weight

  • SW 4024 120/240: 28.1 kg (62.0 lb)
  • SW 4048 120/240: 28.1 kg (62.0 lb)

Shipping Weight

  • SW 4024 120/240: 35.0 kg (77.2 lb)
  • SW 4048 120/240: 35.0 kg (77.2 lb)

Product Dimensions (H x W x D)

  • SW 4024 120/240: 41.8 x 34.1 x 19.7 cm (16.5 x 13.4 x 7.6 in)
  • SW 4048 120/240: 41.8 x 34.1 x 19.7 cm (16.5 x 13.4 x 7.6 in)

Shipping Dimensions (H x W x D)

  • SW 4024 120/240: 56.0 x 44.0 x 32.0 cm (22.0 x 17.3 x 12.6 in)
  • SW 4048 120/240: 56.0 x 44.0 x 32.0 cm (22.0 x 17.3 x 12.6 in)

System Network and Remote Monitoring

  • Available

Safety

  • c(CSA) us mark CSA C22.2, No. 107.1-01 UL 1741 Ed.2

EMC

  • FCC Part 15 Class B

Power Distribution Panels

  • Universal DC distribution panel (865-1016), AC distribution panel (120/240 V) (865-1017)

MPPT Charge Controllers

  • MPPT 100 600 (865-1034), MPPT 80 600 (865-1032), MPPT 60 150 (865-1030-1)

Monitoring

  • InsightHome (865-0330), InsightFacility (865-0335), Insight

Accessories

  • Automatic Generator Start (865-1060-01), Battery Monitor (865-1080-01), Configuration Tool (865-1155-01)
show more